Home News

company news about How to Select a Metalens in a Laser Marking System

I'm Online Chat Now
Company News
How to Select a Metalens in a Laser Marking System
Latest company news about How to Select a Metalens in a Laser Marking System

Metalenses are very suitable for laser processing, as they provide a long depth of focus and can easily and accurately mark and process various non planar objects.

 

latest company news about How to Select a Metalens in a Laser Marking System  0

 

Compared with traditional f-theta marking systems, the metalens marking system has the following advantages:

  • Ultra long depth of field (>75 mm), marking on non-planar surfaces does not require Z-axis movement and can also make markings of consistent line thickness on non-planar surfaces, making it particularly suitable for 3D printing or non-planar machining.
  • Due to the elimination of f-theta lens, the size of the scanning and marking head has decreased significantly.
  • Low cost, mass production.
  • Metalens for any laser wavelength is customizable.
  • Suitable for laser applications of all power levels, low-power laser applications can be used without coatings.

latest company news about How to Select a Metalens in a Laser Marking System  1

Choosing a suitable metalens mainly considers laser wavelength, aperture (diameter of incident laser beam), effective focal length, depth of focus, diameter of focused spot, and laser power. At a laser power of around 50W, the metalens can operate stably without the need for coating. Choose the effective focal length based on the size of the marking area. The longer the focal length, the larger the marking area, but the larger the focusing spot. Therefore, it is necessary to choose a reasonable effective focal length.

Assuming that the distance from the metalens to the second scanning mirror is L1, the distance from the second scanning mirror to the working surface is L2, and the effective focal length of the metalens is EFL, then EFL=L1+L2. If the maximum scanning angle of the galvanometer is θ, The distance between the center focus and the edge focus is the radius R of the marking area, R=TAN(θ)* L2, R, the defocus amount at the outermost edge called as L3 is L3=L2/COSIN(θ)- L2, the defocus amount should be less than 1/2 of the depth of focus, and the marking will be as clear and uniform as the marking on the focal plane.

Assuming the side length of the square marking area and the maximum scanning optical angle of the galvanometer is ± 20 degrees, assuming L1=50mm, calculate the center wavelength and defocus amount of the metalens ± L3 as shown in the table below. When selecting the effective focal length EFL of the metalens, L1, which is the distance from the metalens to the second scanning mirror, also needs to be considered. That is, the effective focal length of the metalens EFL=L1+L2.

Marking area side length

mm

Marking area radius R

mm

Maximum scanning angle

θ

L2

mm

Effective focal length EFL

mm

Defocus L3

mm

50x50 35.36 0.35 97.14 147.14 6.23
75x75 53.03 0.35 145.71 195.71 9.35
100x100 70.71 0.35 194.28 244.28 12.47
125x125 88.39 0.35 242.84 292.84 15.59
150x150 106.07 0.35 291.41 341.41 18.70
200x200 141.42 0.35 388.55 438.55 24.94
250x250 176.78 0.35 485.69 535.69 31.17
300x300 212.13 0.35 582.83 632.83 37.40
350x350 247.49 0.35 679.97 729.97 43.64
400x400 282.84 0.35 777.10 827.10 49.87

The following figure shows the marking effect at different distances between the marking surface and the metalens, with a defocus of up to 75mm. The marks are clear.

latest company news about How to Select a Metalens in a Laser Marking System  2

The following table shows the range of parameters of some of our products:

wavelength Effective focal length EFL Depth of focus (DOF) diameter Spot size
355 nm 25-100 mm 25, 50 mm 3-6 mm 25-250 um
532 nm 25-100 mm 25, 50 mm 3-6 mm 25-250 um
1064 nm 25-100 mm 25, 50 mm 3-6 mm 25-250 um
10.6 um 25-100 mm 25, 50 mm 3-6 mm 50-250 um

 

 

 

 

 

 

 

 

 

 